640×512, 12 μm Pixel VOx LWIR Thermal Core

组合 1.webp
LWIR1203OG-NC LWIR Thermal Core
The LWIR1203OG-NC is a high-performance, high-sensitivity general-purpose LWIR network thermal measurement core. It adopts a 640×512 VOx uncooled focal plane array (FPA) detector with 12 μm pixel pitch. It delivers sharp thermal imaging and precise temperature measurement within the 8–14 μm long-wave infrared band, with thermal sensitivity (NETD) ≤40 mK for stable and reliable operation.
This thermal core supports multiple lens options, including 6.6/9.1/13/15/19/25/35 mm athermal fixed-focus lenses and 19/25/35 mm fixed-focus motorized focus lenses, to flexibly meet different field-of-view and working distance requirements.

Features

  • Spectral Response: 8–14 μm
  • Resolution: 640×512, 12 μm pixel pitch
  • Excellent thermal sensitivity: NETD ≤40 mK, stable operation
  • Temperature measurement accuracy: ±2 ℃ or ±2% 
  • Compatible with major network protocols: ONVIF, GB28181, RTSP, DHCP
Web Access
AttosTek provides comprehensive web access capabilities. The device supports mainstream network protocols including ONVIF, GB28181, RTSP and DHCP. Open SDK and API interfaces are available for fast integration with a wide range of systems and platforms.
Images captured by LWIR camera
The LWIR1203OG-NC LWIR thermal core integrates high-sensitivity long-wave infrared detection with network integration. It enables non-contact temperature monitoring and real-time thermal imaging perception. It can capture temperature anomalies and identify hidden thermal faults without touching targets. Typical application scenarios: online monitoring of industrial equipment and pipelines (early warning of overheating and leakage risks to avoid unplanned shutdowns); inspection of high & low-voltage power equipment (detect overheating defects on connectors, switchgears and cables); forest fire prevention and wildfire monitoring (long-range early fire spot detection); warehouse safety monitoring (warning of spontaneous combustion hazards of stored goods). It delivers a stable, user-friendly and cost-effective solution for industrial users.
Category Parameter Specification
LWIR Thermal Imaging Detector Type VOx Uncooled Focal Plane Array Detector
Resolution 640×512
Pixel Pitch 12 μm
Spectral Range 8~14 μm
Thermal Sensitivity (NETD) ≤40 mK
Thermal Lens 6.6/9.1mm; Athermal Fixed-focus Lens, F=1.0
Field of View 60.3°×49.9° / 45.8°×37.3°
Minimum Focus Distance ≤1 m
Image Enhancement Supported
Electronic Zoom ×1 / ×2 / ×4 / ×8
Color Palette 14 types including White Hot, Black Hot, Iron Red, etc.
Temperature Measurement Range Range 1: -20°C~150°C; Range 2: 140°C~600°C
Accuracy: Max(±2°C, ±2%)
Measurement Targets Supports point, line and area temperature measurement. Area shapes include circle, rectangle and irregular polygon. Up to 21 measurement targets.
Video & Audio Video Compression Standard H.265, H.264
Supported Resolution Thermal Image: Main stream (1280×1024, 640×512), default 1280×1024; Sub stream 640×512
Frame Rate Main stream: 1fps~25fps configurable, default 25fps
Sub stream: 1fps~25fps configurable, default 15fps
Image Format JPEG
Functions UI Language Chinese / English
Two-way Audio Supported
Network Protocols HTTP, HTTPS, TCP, ARP, RTSP, RTP, UDP, RTCP, SMTP, FTP, DHCP, DNS, IPv4/IPv6, NTP
Access Standard ONVIF, GB/T28181-2022; Compatible with general monitoring platforms, power inspection platforms, Uniview platforms
API ISAPI, SDK supported
Interfaces Ethernet Port RJ45, 100M/1000M adaptive
RS-485 Port 1 channel
Alarm Input 1 channel
Alarm Output 1 channel
Power Supply Power Input DC12V
Power Consumption ≤2.5 W
Environmental Operating Temperature -30°C ~ +60°C
Operating Humidity ≤90% RH (non-condensing)
Storage Temperature -50°C ~ +70°C
Physical Dimension 45×45 mm
Weight 216 g
LWIR1203OG-NC LWIR Camera Core
长波红外相机.webp
Parameter Specification
Size 45×45mm×80.9mm
Camera lens interface outer ring Φ36
Network interface
It is a standard RJ45 network port with T568B wiring sequence.
电路 E1793093767836.webp
Pin No. Wire Color Signal Signal Description
1 White-Orange TX+ Transmit Differential +
2 Orange TX- Transmit Differential –
3 White-Green RX+ Receive Differential +
4 Blue NC No Connection
5 White-Blue NC No Connection
6 Green RX- Receive Differential –
7 White-Brown NC No Connection
8 Brown NC No Connection
10 pin terminal interface
接口图.webp
No. Signal ID Type Description
1 DC12V+ Power Input DC12V power supply for the whole device, power consumption ≤2.5W; Overvoltage is strictly prohibited
2 GND Power Ground Common ground for device power and signals
3 485-A / 485+ RS-485 Half-duplex Terminal A Serial communication for lens focus adjustment and external PTZ control; A and B terminals must not be reversed
4 485-B / 485- RS-485 Half-duplex Terminal B Negative differential terminal of RS485; A 120Ω terminating resistor is recommended at the bus end
5 ALM_IN Alarm Input 1-channel dry-contact alarm input; Triggered when shorted to GND, compatible with external sensors
6 ALM_OUT_COM Alarm Output Common Terminal Relay output, 1-channel alarm output, activated on over-temperature / temperature-difference alarm
7 ALM_OUT_NO Alarm Output Normally Open Conducts between COM and NO upon alarm trigger; for connecting external sound-light alarm
8 AUDIO_IN Audio Input Microphone input, supports two-way audio
9 AUDIO_OUT Audio Output Speaker output for two-way audio
10 AUDIO_GND Audio Ground Reference ground for audio signals
Users can access the device’s WEB interface via a web browser to operate, configure and maintain the device. The operation steps are as follows:

1. Open your web browser, enter the IP address 192.168.1.168 in the address bar, and press the Enter key. The login page will appear once the connection is established.

Image.webp

2. Enter the username and password. 
Username: admin, Password: admin123.
Click Login. After successful login, the live preview page will be displayed.

Image 1.webp
产品反馈表单

640 × 512 LWIR Uncooled VOx Camera

Item
Docs
Available
Price
Qty

LWIR1203OG-NC

8-14 μ m VOx LWIR Camera core, 640 × 512 resolution, 12 μ m pixel size

2 Weeks
$900.00

Application Cases

Substation, power distribution and transmission line condition monitoring: Real-time detection of overheating risks on switch cabinets, connectors and busbars for early warning of electrical thermal faults.On-line inspection of industrial equipment: Non-contact thermal imaging temperature measurement for motors, pipelines, pressure vessels and other assets to identify overheating anomalies and prevent unplanned shutdowns.