640×512, 12 μm Pixel VOx LWIR Thermal Core

This thermal core supports multiple lens options, including 6.6/9.1/13/15/19/25/35 mm athermal fixed-focus lenses and 19/25/35 mm fixed-focus motorized focus lenses, to flexibly meet different field-of-view and working distance requirements.
Features
- Spectral Response: 8–14 μm
- Resolution: 640×512, 12 μm pixel pitch
- Excellent thermal sensitivity: NETD ≤40 mK, stable operation
- Temperature measurement accuracy: ±2 ℃ or ±2%
- Compatible with major network protocols: ONVIF, GB28181, RTSP, DHCP
| Category | Parameter | Specification |
| LWIR Thermal Imaging | Detector Type | VOx Uncooled Focal Plane Array Detector |
| Resolution | 640×512 | |
| Pixel Pitch | 12 μm | |
| Spectral Range | 8~14 μm | |
| Thermal Sensitivity (NETD) | ≤40 mK | |
| Thermal Lens | 6.6/9.1mm; Athermal Fixed-focus Lens, F=1.0 | |
| Field of View | 60.3°×49.9° / 45.8°×37.3° | |
| Minimum Focus Distance | ≤1 m | |
| Image Enhancement | Supported | |
| Electronic Zoom | ×1 / ×2 / ×4 / ×8 | |
| Color Palette | 14 types including White Hot, Black Hot, Iron Red, etc. | |
| Temperature Measurement Range | Range 1: -20°C~150°C; Range 2: 140°C~600°C Accuracy: Max(±2°C, ±2%) |
|
| Measurement Targets | Supports point, line and area temperature measurement. Area shapes include circle, rectangle and irregular polygon. Up to 21 measurement targets. | |
| Video & Audio | Video Compression Standard | H.265, H.264 |
| Supported Resolution | Thermal Image: Main stream (1280×1024, 640×512), default 1280×1024; Sub stream 640×512 | |
| Frame Rate | Main stream: 1fps~25fps configurable, default 25fps Sub stream: 1fps~25fps configurable, default 15fps |
|
| Image Format | JPEG | |
| Functions | UI Language | Chinese / English |
| Two-way Audio | Supported | |
| Network Protocols | HTTP, HTTPS, TCP, ARP, RTSP, RTP, UDP, RTCP, SMTP, FTP, DHCP, DNS, IPv4/IPv6, NTP | |
| Access Standard | ONVIF, GB/T28181-2022; Compatible with general monitoring platforms, power inspection platforms, Uniview platforms | |
| API | ISAPI, SDK supported | |
| Interfaces | Ethernet Port | RJ45, 100M/1000M adaptive |
| RS-485 Port | 1 channel | |
| Alarm Input | 1 channel | |
| Alarm Output | 1 channel | |
| Power Supply | Power Input | DC12V |
| Power Consumption | ≤2.5 W | |
| Environmental | Operating Temperature | -30°C ~ +60°C |
| Operating Humidity | ≤90% RH (non-condensing) | |
| Storage Temperature | -50°C ~ +70°C | |
| Physical | Dimension | 45×45 mm |
| Weight | 216 g |

| Parameter | Specification |
| Size | 45×45mm×80.9mm |
| Camera lens interface outer ring | Φ36 |

| Pin No. | Wire Color | Signal | Signal Description |
| 1 | White-Orange | TX+ | Transmit Differential + |
| 2 | Orange | TX- | Transmit Differential – |
| 3 | White-Green | RX+ | Receive Differential + |
| 4 | Blue | NC | No Connection |
| 5 | White-Blue | NC | No Connection |
| 6 | Green | RX- | Receive Differential – |
| 7 | White-Brown | NC | No Connection |
| 8 | Brown | NC | No Connection |

| No. | Signal ID | Type | Description |
| 1 | DC12V+ | Power Input | DC12V power supply for the whole device, power consumption ≤2.5W; Overvoltage is strictly prohibited |
| 2 | GND | Power Ground | Common ground for device power and signals |
| 3 | 485-A / 485+ | RS-485 Half-duplex Terminal A | Serial communication for lens focus adjustment and external PTZ control; A and B terminals must not be reversed |
| 4 | 485-B / 485- | RS-485 Half-duplex Terminal B | Negative differential terminal of RS485; A 120Ω terminating resistor is recommended at the bus end |
| 5 | ALM_IN | Alarm Input | 1-channel dry-contact alarm input; Triggered when shorted to GND, compatible with external sensors |
| 6 | ALM_OUT_COM | Alarm Output Common Terminal | Relay output, 1-channel alarm output, activated on over-temperature / temperature-difference alarm |
| 7 | ALM_OUT_NO | Alarm Output Normally Open | Conducts between COM and NO upon alarm trigger; for connecting external sound-light alarm |
| 8 | AUDIO_IN | Audio Input | Microphone input, supports two-way audio |
| 9 | AUDIO_OUT | Audio Output | Speaker output for two-way audio |
| 10 | AUDIO_GND | Audio Ground | Reference ground for audio signals |
1. Open your web browser, enter the IP address 192.168.1.168 in the address bar, and press the Enter key. The login page will appear once the connection is established.

2. Enter the username and password.
Username: admin, Password: admin123.
Click Login. After successful login, the live preview page will be displayed.

Q1: What problems can this thermal camera core solve in power inspection applications?
In power inspection, equipment overheating is one of the critical early warning signs of failure. The LWIR1203OG-NC supports two temperature measurement ranges (-20℃~150℃ and 140℃~600℃) with temperature accuracy of ±2℃ or ±2%. It enables non-contact temperature measurement on key components such as transformer bushings, switch contacts and cable clamps. It supports flexible configuration of up to 21 measurement targets to monitor multiple critical points simultaneously. An alarm will be triggered when the temperature exceeds the preset threshold, helping operation and maintenance staff perform predictive maintenance and prevent failures in advance.
Q2: What does the thermal sensitivity NETD ≤40 mK mean for this series core?
NETD (Noise Equivalent Temperature Difference) is a key parameter to evaluate the sensitivity of LWIR thermal cores. NETD ≤40 mK means the detector can resolve tiny temperature differences as low as 0.04℃, delivering excellent detection performance for low-ΔT scenarios such as subtle temperature rise on power equipment and minor pipeline leakage. The temperature accuracy specification of LWIR1203OG-NC is Max(±2℃, ±2%), which means the guaranteed accuracy is the larger value between ±2℃ and ±2% of the reading.
Q3: Will changes in ambient temperature affect temperature measurement accuracy?
Infrared detectors have inherent non-uniformity. Variations in ambient temperature will alter the detector’s non-uniformity and degrade temperature measurement accuracy.
Mitigation measures: Operate the thermal core within its rated operating temperature range of -30℃ ~ +60℃; set the ambient temperature compensation parameters correctly in the measurement software; perform periodic shutter correction to reduce image noise caused by temperature drift. For high-precision temperature measurement tasks, stable ambient temperature is recommended.
640 × 512 LWIR Uncooled VOx Camera
LWIR1203OG-NC
8-14 μ m VOx LWIR Camera core, 640 × 512 resolution, 12 μ m pixel size